        Gas transmitter - ADOS LCTR 903

        The gas transmitter ADOS GTR 196 is suitable for continuous measurement of gases in normal areas and areas where there is a risk of explosion.
        By employing 5 different types of sensor, noxious, explosive and non-combustible gases and vapours can be measured.
        A current signal is generated that is proportional to the measured concentration of gas, which is transmitted to an evaluation unit placed in a safe area, away from any dangers of explosion.
        The type test of the explosion-protected gas transmitter, is completed by the KEMA.

        TGS sensor

        The TGS sensor contains a semiconductor sensor, which is constructed on SnO2-sintered N-substrate. When combustible or reducing gases are absorbed by the surface of the sensor, the concentration of the test gas is determined by the change in conductivity.

        VQ sensor

        The head of the VQ sensor functions on the principle of heat reaction. When combustible or reducing gases or vapours come in contact with the measuring element, they are subjected to catalytic combustion, which causes a rise in temperature; this rise causes a change in the resistance of the measuring element which is used as a measure of the component of gas being tested.

        The inert element is for compensating the temperature and conductivity of the test gas.

        GOW sensor

        The GOW sensor functions on the principle of thermal conductivity. Two rhenium-tungsten resistors are used as a measuring element, where the comparison element is subjected to normal ambient air and the measuring element is subjected to the test gas. Any change in the concentration of gas at the measurement element causes a change in temperature, which is due to the variation of conductivity.

        The resultant change in resistance is a direct measure of the gas concentration.


        TOX sensor

        The TOX sensor is a measurement system with an electro-chemical cell, where the sampled gas is measured by diffusion. In the case of oxygen measurement the oxygen content is reduced in an electrolyte, thus producing a small flow of current (electro-chemical process). At a constant air pressure, this current is directly proportional to the oxygen concentration in the sampled air.

        The IR sensor

        The test gas flows through a measurement chamber that incorporates an IR radiating source and a two-channel infrared detector. The intensity of the infrared radiation is reduced as it passes through the gas molecules. The concentration of the gas can then be calculated by the magnitude of the reduction in intensity. Since only absorption of the wavelength (A) specific to the gas under test in relation to the wavelength (B) not absorbed by a test gas is considered, interference due to dust, ageing etc., is almost fully compensated.

        Feature
        • Chemical industry

        • Manufacture of paints and varnishes

        • Plastics processing plants

        • Sewage works

        • Gas-fired boiler systems

        • Liquid gas storage houses

        • Laboratories

        • Oxygen concentration measurements

        • Refineries

        • Cold storage houses (Ammonia monitoring)

        • Paint spraying booths

        • and many more.

        TypeTGSVQGOW
        Measurement methodSemiconductorHeat reductionThermal conductivity
        Measurement range

        ppm ranges to 100 % LEL

        ppm ranges to 100 % LEL

        from 0-5 Vol % to 0-100 Vol %

        Percentage error of f.s.d.±5 %±3 %±5 %
        Temperature range-25 °C to +55 °C-25 °C to +55 °C-25 °C to +55 °C
        Temperature effect3 %2 %3 %
        Response time (t90)approx. 55 sec.approx. 40 sec.approx. 55 sec.
        Pressure effect (atm.)1 %1 %1 %
        Mounting positionoptionaloptionaloptional
        ApplicationPoisonous, combustible and explosive gases in the LEL regionPoisonous, combustible and explosive gases in the LEL regionGases exhibiting substantial differences in thermal conductivity, compared to air
        Versions availableindustrial (Al), industrial (VA)- and Ex-versionindustrial (Al), industrial (VA)- and Ex-versionindustrial (Al), industrial (VA)- and Ex-version
        Service life of the sensorunlimited, when used for gases not causing catalytic poisoningunlimited, when used for gases not causing catalytic poisoningunlimited, when used with gases that do not attack aluminium, rhenium-tungsten or gold
        Supply voltage15 – 30 V15 – 30 V15 – 30 V
        Interfaces3-wire techniques 4-20 mA or LON? 4-wire techniques, galvanically isolated, data transfer 78 kB/s

        3-wire techniques 4-20 mA or LON? 4-wire techniques, galvanically isolated, data transfer 78 kB/s

        3-wire techniques 4-20 mA or LON? 4-wire techniques, galvanically isolated, data transfer 78 kB/s
        Protection

        II 2 G

        Ex demb [ia] IIC T

        II 2 G

        Ex demb [ia] IIC T6

        II 2 G

        Ex demb [ia] IIC T6

        Ex-Version

        KEMA 03 ATEX 2403 X

        KEMA 03 ATEX 2403 XKEMA 03 ATEX 2403 X
        Protection classIP 54IP 54IP 54

        Dimensions
        (W x H x D)

        150 x 170 x 105 mm150 x 170 x 105 mm150 x 170 x 105 mm
        Weight2,7 kg2,7 kg2,7 kg


        TypeTOXIRPID
        Measurement methodElectro-chemical cellInfraredPhoto-Ionisation
        Measurement range

        ppm ranges to 100 LEL %

        0–100 % LEL CH4, C3H8, C2H2,

        0–100 Vol % CH4

        0–1, 2, 3, 4, 5 Vol % CO2

        0 – 200 ppm to

        0 – 2.000 ppm

        Percentage error of f.s.d.± 3%± 2 %± 5 %
        Temperature range-25 °C to +55 °C-25 °C to +55 °C-25 °C to +55 °C
        Temperature effect2 %2 %3 %
        Response time (t90)approx. 60 sec.approx. 45 sec.approx. 120 sec.
        Pressure effect (atm.)1 %4 %1 %
        Mounting positionoptionaloptionaloptional
        Application

        O2, CO, NH3, NO2,SO2, H2S a.o.

        CH4 (Vol %; LEL) Propane (LEL) CO2 (Vol %)e.g. C7H8, C8H10 CHCl3, PH3
        Versions available

        industrial (Al),industrial (VA)- and Ex-version

        industrial (Al),industrial (VA)- and Ex-versionindustrial (Al),industrial (VA)- and Ex-version
        Service life of the sensor12 months to 5 years depending on the measuring cellapprox. 5 years12 monthss
        Supply voltage15 – 30 V15 – 30 V15 – 30 V
        Interfaces3-wire techniques 4-20 mA or LON? 4-wire techniques, galvanically isolated, data transfer 78 kB/s3-wire techniques 4-20 mA or LON? 4-wire techniques, galvanically isolated, data transfer 78 kB/s3-wire techniques 4-20 mA or LON? 4-wire techniques, galvanically isolated, data transfer 78 kB/s
        Protection

        II 2 G

        Ex demb [ia] IIC T

        II 2 G

        Ex demb [ia] IIC T6

        II 2 G

        Ex demb [ia] IIC T6

        Ex-Version

        KEMA 03 

        ATEX 2403 

        KEMA 03 

        ATEX 2403 X

        KEMA 03 

        ATEX 2403 X

        Protection classIP 54IP 54IP 54
        Dimensions (WxHxD)100 x 180 x 80 mm100 x 180 x 80 mm100 x 180 x 80 mm
        Weight1,1 kg1,1 kg1,1 kg


        Gas transmitter
        Contact Us

        400 086 1088

        info@onuee.com

        18925249909

        OTHER RELATED

        ONUEE / ONWARDS(HK) Ltd. All rights reserved  ?2004-  備案號粵ICP備09176163號

        主站蜘蛛池模板: 影院精品久久久无码| 亚洲精品国产自在久久 | 国产超碰人人爽人人做人人添| 夜夜揉揉日日人人| 亚洲国产中文在线| 玩弄放荡人妻少妇系列| 美美女高清毛片视频免费观看| 泗洪县| 亚洲欧洲一区二区三区在线观看| 国产精品大全中文字幕| 亚洲a√无码在线观看| 欧美老熟妇乱子伦视频| 国产精品亚洲成在人线| 亚洲精品二区在线播放| 欧美肥胖老太vidio在线视频| 亚洲欧美日韩中文字幕在线一区| 91日本中文字幕家庭教师| 亚洲自拍偷拍福利小视频| 欧美中文精品有码视频在线| 亚洲va韩国va欧美va| 中文字幕一区二区三区日韩精品| 双江| 色噜噜人体337p人体| 国产精品无码网站| 亚洲综合成人婷婷五月网址| 婷婷丁香视频一区| 国产无套粉嫩白浆内射在线观看 | 久久不见久久见免费影院国语| 精品熟人妻一区二区三区四区不卡| 中文在线最新版天堂| 国产麻豆一精品一av一免费软件| 最近免费中文字幕大全高清10| 蜜臀av性久久久久蜜臀aⅴ麻豆| 亚洲无码片第一区| 公喝错春药让我高潮| 防城港市| 人妻色综合网站| 国产精品久久久久久一区二区三区 | 忘记穿内裤被同桌摸到高潮app| 亚洲 欧洲 无码 在线观看| 9999国产精品欧美久久久久久|